Festool AT 65 E Saw User Manual


 
8
Technical data AT 65 E
Power input 1 500 W
No load speed 1 800 - 3 800 rpm
Angele of cut 0° - 45°
Depth of cut at 90° / 45°) 66 mm (2.6) / 48 mm (1.9)
Saw blade diameter 190 mm (7.5)
Saw blade hole diameter 30 mm (1.18)
Weight 6.7 kg (14.8 lbs)
Safety acc. to IEC 745, UL 745, CSA C22.2 No. 745
1 Symbols
V volts
A amperes
Hz hertz
W watt
~ alternating current
n
0
no load speed
Class II Construction
rpm revolutions per minute
1.1 Spindle stop / Dispositif darrêt de laxe / Dispositivo de
bloqueo del husillo
1.2 Protective cover / Capot de protection / Caperuza
protectora
1.3 Cutting depth scale / Vernier de profondeur de coupe /
Escala de profundidades de corte
1.4 Cutting depth end stop / Butée de profondeur de coupe
/ Tope de profundidad de corte
1.5 Setscrew for angle adjustment / Vis de blocage pour le
réglage en biais / Tornillo de sujeción para regulación
del ángulo de inclinación
1.6 Saw table / Table de scie / Mesa de aserrado
1.7 Switching on and unlocking block / Bouton de mise en
marche et de déverrouillage / Bloqueo de conexión y de
desenclavamiento
1.8 On/Off switch / Interrupteur marche/arrêt / Interruptor
de conexión/desconexión
1.9 Speed controller / Régulateur de vitesse de rotation /
Regulador del número de revoluciones
1.10 Handle / Poignée / Empuñadura
1.11 Additional handle / Poignée supplémentaire /
Empuñadura adicional
1.12 Hexagon socket wrench / Clé mâle hexagonale / Llave
macho hexagonal
1.13 Guide jaws / Joues de guidage / Mordazas de guía
1.14 Screw for adjusting the centre of gravity / Vis de réglage
du point de pivotement / Tornillo para el ajuste del punto
de giro
2.3 Extension cable
If an extension cable is required, it must have a sufficient
cross-section so as to prevent an excessive drop in voltage
or overheating. An excessive drop in voltage reduces the
output and can lead to failure of the motor. The following
table shows you the correct cable diameter as a function of
the cable length for the AT65E. Use only U.L. and CSA listed
extension cables. Never use two extension cables together.
Instead, use one long one.
2.2 Electrical connection
The network voltage must conform to the voltage indicated
on the rating plate. A 16 A safety fuse (for 120 V) or a
corresponding protective circuit-breaker is required.
Under no circumstances should the electrical tool be used
when the power cable is damaged. A damaged cable must be
replaced immediately by an authorised Customer Service
Centre. Do not try to repair the damaged cable yourself. The
use of damaged power cables can lead to an electric shock.
Various dust created by power sanding, sawing,
grinding, drilling and other construction activities contains
chemicals known (to the State of California) to cause cancer,
birth defects or other reproductive harm. Some examples
of these chemicals are:
 lead from lead-based paints,
crystalline silica from bricks and cement and other masonry
products, and
arsenic and chromium from chemically-treated lumber.
The risk from these exposures varies, depending on how
often you do this type of work.
To reduce your exposure to these chemicals: work in a well
ventilated area, and work with approved safety equipment,
such as dust masks that are specially designed to filter out
microscopic particles.
2 Functional description
2.1 Intended use
The AT 65 E is designed exclusively for the sawing of wood,
wood-like materials and plastics. When the AT 65 E is fitted
with the aluminium saw blade (Order no. 486 299), it can also
be used for sawing aluminium. This machine should not be
used for processing other materials.
The machine should not be converted or modified, e.g. for
any other form of use, other than as specified in these
operating instructions.
The user shall be liable for damages and accidents due to
incorrect use.