Freud Tools FT3000VCE Router User Manual


 
15
Mounting Template Guides
WARNING! Disconnect tool from power
source.
For template routing the Freud FT3000 accepts
standard template guides which are available
separately. To use template guides an optional
adapter ring (Freud FT1100) must be attached
to the base plate using the two slotted screws
provided. Remove the slotted screws from the
base plate, insert the adapter ring with the flat
side toward the router body. Install and tighten
the screws to secure the adapter ring. - Fig. 17
The base plate has been centered at the
factory, however, if the base plate has been
removed and remounted some adjustment may
be necessary to center the template guides to
the router bit. To adjust, loosen the four base
plate screws that secure the base plate to the
router, reposition the base plate and tighten the
screws.
OPERATING INSTRUCTIONS
WARNING: Make sure that the voltage from
the power supply matches the voltage specified
on the tool. Before plugging in the tool ensure
that the bit is properly inserted and tightened
and that it spins freely.
1. Powering the Tool On and Off
a) Plug in the tool with the Trigger Switch in
the OFF position and the lock button
released.
b) Hold the router firmly by both
handles with the bit away from you
and positioned so that the bit is not
in contact with the wood or any part
of your body or clothing.
c) Start the tool by depressing the Trigger
Switch. - Fig 18
d) Lock the tool in the run position by
depressing the Locking Button with your
thumb while the Trigger Switch is on.
Release the Locking Button by
momentarily depressing the Trigger Switch
and releasing.
e) Turn off the tool by releasing the Trigger
Switch.
English
Fig. 17
Base Plate
Screw
Adapter Ring
Screws
Base
Plate Screw
Base Plate
Screw
Base
Plate Screw
Fig. 18
ON
Locking
Button
OFF
English FT3000 Manual.indd 15English FT3000 Manual.indd 15 10/18/06 11:57:58 AM10/18/06 11:57:58 AM