Fujitsu MHD2032AT Drill User Manual


 
Interface
5-72 C141-E050-02EN
sector in multiple-sector reading. If the timing to read the Status register does not meet
above condition, normal data transfer operation is not guaranteed.
When the host new command even if the device requests the data transfer (setting in DRQ
bit), the correct device operation is not guaranteed.
Figure 5.4 Protocol for command abort
5.4.2 Data transferring commands from host to device
The execution of the following commands involves Data transfer from the host to
the drive.
WRITE SECTOR(S)
WRITE LONG
WRITE BUFFER
WRITE VERIFY
SECURITY DISABLE PASSWORD
SECURITY ERASE UNIT
SECURITY SET PASSWORD
SECURITY UNCLOK
The execution of these commands includes the transfer one or more sectors of data
from the host to the device. In the WRITE LONG command, 516 bytes are
transferred. Following shows the protocol outline.
a) The host writes any required parameters to the Features, Sector Count, Sector
Number, Cylinder, and Device/Head registers.