Setup
3A1456D 9
Spraying Stains or Clear Coats
(Fine-Finish Optimizer)
The Fine-Finish Optimizer should be installed and used
when spraying thin material such as stain or clear coats.
The Fine-Finish Optimizer restricts the material flow
resulting in a finer quality finish.
Installation
1. Remove material cup and suction tube.
2. Push Fine-Finish Optimizer into pump inlet until
completely engaged and re-install suction tube.
Cleanup/Storage
Be sure to remove and clean the Fine-Finish Optimizer
immediately after use. Store the Fine-Finish Optimizer
on the Storage/cleaning Tool supplied to keep the hole
clear of dried material.
Sprayer Setup
This sprayer arrives from the factory with a small
amount of test material in the system. It is important
that you flush this material from the sprayer before
using it for the first time:
1. Fill material cup with water and thread onto sprayer.
2. Put prime/relief valve to UP position, then hold trig-
ger in for 10 seconds.
3. Put prime/relief valve DOWN to spray position.
4. Reverse spray tip to UNCLOG position and trigger
sprayer into a waste area.
5. Engage trigger lock and put prime/relief valve UP to
release pressure.
6. Unscrew and remove material cup.
7. Disengage trigger lock, put prime/relief valve
DOWN, hold sprayer slightly above material cup,
and pull trigger to discharge fluid from pump.
8. Discard material in cup.
ti15440a
ti15473a
ti14992a
ti14999a
ti15425a
ti14991a
ti15491a
ti14999a
ti14994a
ti15478a