Graco 308371K Saw User Manual


 
4 308371
Installation
WARNING
FIRE AND EXPLOSION HAZARD
Always maintain a minimum of 1 in.
clearance between rotating agitator parts
and container to prevent sparks from contact.
air line lubricator
agitator motor
air line filter
air regulator
and gauge
mix tank
(reference only)
Typical Installation
NOTE: Reference numbers and letters in parentheses
refer to the numbers and letters in the Figures and the
Parts Drawings.
Grounding
Proper grounding is an essential part of maintaining a
safe system.
To reduce the risk of static sparking, all electrically
conductive objects or devices must be properly
grounded. Check your local electrical code for detailed
grounding instructions for your area and type of
equipment.
To ground the agitator, connect one end of the
ground wire (A) to the ground connector (B) on agitator
mounting bracket. See Fig. 1. Connect the other end
of the ground wire to a true earth ground.
For a ground wire and clamp, order
Part No. 237569.
A
Fig. 1
B
Pressure Relief Procedure
WARNING
To reduce the risk of serious bodily injury, including
splashing in the eyes or on the skin, or injury from
moving parts, which can result if the tank pressure
is not fully relieved, always follow this procedure
before opening the pressure tank cover or fill port.
1. Shut off the air supply to the tank by closing the air
inlet valve (A). Refer to Fig. 2.
2. Open the drain cock fitting (B) by turning it
counterclockwise.
3. Wait until there is no air escaping through the
fitting before removing the cover or opening the fill
port.
4. Leave the drain cock fitting open until you have
reinstalled the cover or filler cap.