Operation
10 311322K
Air Hose Configurations
The GAP Pro Gun has two possible air hose
configurations. In the standard configuration,
the air connection is at the base of the handle.
In the optional configuration, the air connection
is at the rear of the gun.
1. See FIG. 6. Remove air hose from nipple at
base of gun handle.
2. Remove nipple from gun handle.
3. Remove pipe plug from back of gun.
4. Install pipe plug in base of gun handle.
5. Install nipple in back of gun.
6. Connect air hose to nipple and use wrench
to tighten.
Always engage safety stop, close both man-
ual valves, and disconnect air before chang-
ing air hose configuration.
FIG. 6. Air Hose Configuration
2
!
Air Hose
Install Pipe Nipple
Remove
Pipe Plug
Install Pipe Plug
Remove Long Pipe Nipple