Operation
332245E 11
7. Place drain tube in a grounded waste pail.
Open drain/purge valve (S) slightly by rotating coun-
terclockwise.
8. Start the pump by rotating the air regulator adjust-
ment knob (E) clockwise until pump begins to move.
9. When clean solvent flows from drain tube close
drain/purge valve (S) by rotating clockwise. Pump
will stall.
10. Follow Pressure Relief Procedure, page 9. Leave
solvent in and store sprayer.
Prime
1. Follow Pressure Relief Procedure, page 9.
2. See F
IG
. 1. Lock gun trigger. Remove tip guard and
spray tip from gun (H). Refer to gun manual.
3. Place suction tube in a compatible fluid.
NOTE: Do not stretch hose tight; let it hang to assist
fluid flow into pump.
4. Turn regulator adjustment knob (E) counterclock-
wise until it stops, and gauge (D) reads zero.
5. Open bleed type master air valve (C).