Graco ti13586a Paint Sprayer User Manual


 
Air Flow
8 313516G
Air Flow
See the chart to determine air consumption. Add the air consumption values shown for the atom-
izing air and fan air pressures to get the total air consumption. For example, air cap 24B544 with
20 psi atomizing air pressure uses 3 scfm atomizing air. A 30 psi fan inlet pressure adds 5 scfm
fan air for a total of 8 scfm air consumption.
Air cap
Atomizing Air Fan Air
Manifold Inlet Pressure
psi (MPa, bar)
Air Flow
SCFM
Manifold Inlet Pressure
psi (MPa, bar)
Air Flow
SCFM
289773
10 (0.07, 0.7) 2 10 (0.07, 0.7) 2
20 (0.14, 1.4) 3 20 (0.14, 1.4) 4
30 (0.21, 2.1) 5 30 (0.21, 2.1) 5
40 (0.28, 2.8) 7 40 (0.28, 2.8) 7
50 (0.34, 3.4) 8 50 (0.34, 3.4) 9
289041
10 (0.07, 0.7) 3 10 (0.07, 0.7) 4
20 (0.14, 1.4) 7 20 (0.14, 1.4) 7
30 (0.21, 2.1) 10 30 (0.21, 2.1) 11
40 (0.28, 2.8) 13 40 (0.28, 2.8) 14
50 (0.34, 3.4) 17 50 (0.34, 3.4) 18
17* (0.12, 1.2) 6 29* (0.20, 2.0) 10
288861
10 (0.07, 0.7) 2 10 (0.07, 0.7) 2
20 (0.14, 1.4) 4 20 (0.14, 1.4) 5
30 (0.21, 2.1) 6 30 (0.21, 2.1) 7
40 (0.28, 2.8) 8 40 (0.28, 2.8) 10
50 (0.34, 3.4) 11 50 (0.34, 3.4) 12
289115
10 (0.07, 0.7) 3 10 (0.07, 0.7) 4
20 (0.14, 1.4) 7 20 (0.14, 1.4) 7
30 (0.21, 2.1) 10 30 (0.21, 2.1) 11
40 (0.28, 2.8) 14 40 (0.28, 2.8) 15
50 (0.34, 3.4) 17 50 (0.34, 3.4) 19
18* (0.12, 1.2) 6 28* (0.19, 1.9) 10
289050
10 (0.07, 0.7) 1 10 (0.07, 0.7) 2
20 (0.14, 1.4) 3 20 (0.14, 1.4) 4
30 (0.21, 2.1) 4 30 (0.21, 2.1) 6
40 (0.28, 2.8) 5 40 (0.28, 2.8) 8
50 (0.34, 3.4) 7 50 (0.34, 3.4) 10
28* (0.19, 1.9) 4 31* (0.21, 2.1) 6
288862
10 (0.07, 0.7) 2 5 (0.035, 0.35) 1
20 (0.14, 1.4) 4 10 (0.07, 0.7) 3
30 (0.21, 2.1) 6 15 (0.10, 1.0) 4
40 (0.28, 2.8) 7 20 (0.14, 1.4) 5
50 (0.34, 3.4) 9 25 (0.17, 1.7) 7