Graco Inc. 240369 Paint Sprayer User Manual


 
5308846
Setup
Hose Connections
This package is shipped with the hoses connected.
Before you disconnect any hoses, make a note of the
proper connections.
Flush Pump Before First Use
The pump was tested in water. If the test solution
could contaminate the fluid you are pumping, flush the
pump thoroughly with a compatible solvent. See
Flushing the System on page 8.
Grounding
WARNING
To reduce the risk of static sparking, the entire
system must be grounded. Check your local
electrical code for detailed grounding instructions
for your area and type of equipment. Ground all of
this equipment.
Also read FIRE AND EXPLOSION
HAZARD on page 2.
D
Pump:
One end of the ground wire is already
connected to the pump grounding strip. Connect
the clamp end of the ground wire to a true earth
ground.
D
Air compressor:
Follow the manufacturer’s
recommendations.
D
Object being sprayed:
Follow the local code.
D
Fluid supply container:
Follow the local code.
D
All solvent pails used when flushing:
Follow the
local code. Use only metal pails, which are
conductive. Do not place the pail on a
non-conductive surface, such as paper or
cardboard, which interrupts the grounding
continuity.
D
Systems with PRO
3500sc and PRO 4500sc
electrostatic gun:
Make sure you read all of the
grounding instructions and warnings in your gun
instruction manual.