Graco Inc. 309295L Paint Sprayer User Manual


 
Repair
24 309295L
Repair
Pressure Relief Procedure
1. Turn the ES ON/OFF valve OFF.
2. Lock the trigger.
3. Turn off the air bleed valves to the fluid source and
to the gun.
4. Unlock the trigger.
5. Trigger the gun into a grounded metal waste con-
tainer to relieve the fluid pressure.
6. Lock the trigger.
7. Open the pump drain valve and all other fluid drain
valves in the system, having a waste container
ready to catch the drainage. Leave the drain
valve(s) open until you are ready to spray again.
8. If the nozzle or hose is completely clogged or pres-
sure is not fully relieved, slowly loosen the hose end
coupling. Now clear the nozzle or hose.
WARNING
Skin Injection Hazard
The system pressure must be manually
relieved to prevent the system from starting
or spraying accidentally. Fluid under high
pressure can be injected through the skin
and cause serious injury. To reduce the risk of an
injury from injection, splashing fluid, or electric shock,
follow the Pressure Relief Procedure whenever you:
are instructed to relieve the pressure
stop spraying
check or repair any of the system equipment
or install or clean the spray tip.
I O
ES
ti1337a
ti1356a
ti1289a
ti1406a
ti1341a
ti1356a
ti1290a
t