Pressure Relief Procedure
6 313384B
Pressure Relief Procedure
1. Turn OFF air inlet valve (E).
2. Open gun air valve (23).
3. Trigger gun. Spray material back into hopper (G).
To reduce the risk of injury, follow this Pressure Relief
Procedure whenever you:
• Are instructed to relieve pressure
• Stop spraying
• Service equipment
• Install or clean spray nozzle
• Disconnect or connect hose
E
TI
23
G