Grizzly G0489 Sander User Manual


 
G0489 Metalworking Sander
-15-
Figure 13. Rest installation.
Rest Lever
Square Nut
Rest
Dust Collection
The Model G0489 comes with a 4" dust port
ready to attach to your metal dust collection sys
-
tem. Your dust collection system is unique so we
cannot give you specific instructions to cover all
the possible set up options.
To connect a dust collection hose:
1. Fit your dust hose over the dust port and
secure in place with a hose clamp
.
DO NOT operate the Model G0489 with a
dust collection system that has been previ
-
ously used for wood dust collection or other
combustible material. Hot metal sparks and
fragments could cause material to ignite! DO
NOT attach to plastic fittings or dust collec
-
tion system not rated specifically for metal
dust collection!
Test Run
Once the assembly is complete, test run your
machine to make sure it runs properly.
If, during the test run, you cannot easily locate
the source of an unusual noise or vibration, stop
using the machine immediately.
If you cannot remedy a problem, contact our Tech
Support at (570) 546-9663 for assistance.
To test run the machine:
1. Connect the machine to the power source.
2. Make sure you have read the safety instruc-
tions at the beginning of the manual and that
the machine is setup properly.
3. Make sure all tools and objects used during
set up are cleared away from the machine.
4. Turn the machine ON.
5. Listen to and watch for abnormal noises or
actions. The machine should run smoothly
with little or no vibration or rubbing noises.
Strange or unusual noises should be inves
-
tigated and corrected before operating the
machine further. Always disconnect the
machine from power when investigating or
correcting potential problems.