SECTION 2: CIRCUIT REQUIREMENTS
Amperage Draw
The motor for your machine may draw the follow-
ing amps at maximum load.
G0513X at 220V Single-Phase ............. 10 Amps
G0513X at 110V* .................................. 20 Amps
G0514X at 220V Single-Phase ............. 16 Amps
G0514X3 at 220V 3-Phase ..................... 9 Amps
G0514X3 at 440V 3-Phase** ............... 4.5 Amps
Circuit Requirements
We recommend connecting this machine to a
dedicated circuit with a verified ground, using the
circuit breaker size given below. Never replace a
circuit breaker with one of higher amperage with
-
out consulting a qualified electrician to ensure
compliance with wiring codes
. If you are unsure
about the wiring codes in your area or you
plan to connect your machine to a shared cir
-
cuit, you may create a fire hazard—consult a
qualified electrician to reduce this risk.
G0513X at 220V .............
15 Amp Circuit Breaker
G0513X at 110V* ...........
30 Amp Circuit Breaker
G0514X ..........................20 Amp Circuit Breaker
G0514X3 at 220V ...........
15 Amp Circuit Breaker
G0514X3 at 440V** ........15 Amp Circuit Breaker
* To run on 110V, you MUST rewire the motor.
Refer to the wiring diagram on Page 54
.
** To run on 440V, you must rewire the motor
and replace the 220V magnetic switch assem
-
bly with the 440V magnetic switch assembly
(Part #P0514X3161A)
. Refer to the wiring dia-
gram on Page 58 for wiring details.
Figure 3. NEMA 6-15 plug and receptacle.
Figure 4. NEMA 5-30 plug and receptacle.
Plug Type
The cord set enclosed does not have a plug as
the style of plug you require will depend upon
the type of service you currently have or plan to
install. We recommend using the following plugs
for your machine on a dedicated circuit only (see
Figures
3–6 for examples):
G0513X at 220V ....................... NEMA 6-15 Plug
G0513X at 110V* ..................... NEMA 5-30 Plug
G0514X .................................... NEMA 6-20 Plug
G0514X3 at 220V ..................NEMA L15-20 Plug
G0514X3 at 440V** ................NEMA L16-20 Plug