Grizzly G0588 Saw User Manual


 
-14-
G0588/G0591 12" Sliding Table Saws
In the event of an electrical short, grounding
reduces the risk of electric shock. The ground
-
ing wire in the cord must be properly connected
to the grounding prong on the plug; likewise, the
outlet must be properly installed and grounded.
All electrical connections must be made in accor
-
dance with local codes and ordinances.
Improper connections of the electrical-grounding
conductor increases the risk of electric shock.
Check with a qualified electrician or one of our
service personnel if you do not understand
the grounding instructions, or if you doubt the
machine is properly grounded.
Grounding
Electrocution or fire could
result if this machine is
not grounded correctly
or if your electrical con
-
figuration does not com
-
ply with local and state
codes. Ensure compliance
by checking with a quali
-
fied electrician!
The Model G0588 can be rewired for 440V oper-
ation. This rewiring job consists of disconnecting
the saw from the power source, replacing the
magnetic switch, and rewiring the motor.
The necessary magnetic switch for this proce
-
dure can be purchased by calling our Customer
Service number at (800) 523-4777.
This procedure takes moderate electrical skill
and the rewiring job must be inspected by a quali-
fied electrician before the saw is connected to the
power source.
To rewire the Model G0588 for 440V opera-
tion:
1. Disconnect the saw from the power
source!
2. Remove the control panel cover plate shown
in Figure 6.
Rewiring to 440V
Figure 6. Control panel cover plate.
When using a phase converter, the power from
the manufactured power leg (sometimes called
the wild wire) can fluctuate. Connect the manufac
-
tured power leg to the S terminal to prevent dam
-
age to the electrical controls. The wire from the S
terminal can handle some fluctuation because it
goes directly to the motor. The power going to the
R and T terminals goes to the electrical controls
and must be consistent to prevent damage. See
the instruction manual included with the phase
converter for more information.
Phase Converter