SKU 92386 For technical questions, please call 1-800-444-3353. Page 9
POWER CORD
120 VOLT,
GROUNDED
ELECTRICAL
OUTLET
TILE SAW
DRIP LOOP
FIGURE C
Always arrange a “drip loop” in the Power Cord connecting the Tile Saw to a
120 volt, grounded, electrical outlet. A drip loop is that part of the Power Cord
below the level of the outlet, or the connector if an extension cord is used, to pre-
vent water traveling along the Power Cord and coming in contact with the outlet.
If the Power Plug or electrical outlet does get wet, do not unplug the Power Cord.
Disconnect the fuse or circuit breaker that supplies power to the tool. Then, unplug
and examine for presence of water in the outlet. (See Figure C.)
Use cold water only. Never use hot water. Using hot water can damage the
Pump seals.
Never run the Tile Saw without a water supply. Running the unit without a water
supply will cause irreparable damage to the Pump.
Make sure the water supply used for the Tile Saw is not dirty, sandy, and does
not contain any corrosive chemical products.
Make sure to change the water when necessary while in use and rinse out
the Tub after every use.
Never leave the Tile Saw unattended when it is plugged into an electrical outlet.
Turn off the Tile Saw, and unplug it from its electrical outlet.
Always keep the water level at the recommended level. Fill the Tank with enough
water so that the Pump is about 3/4 completely submerged, but not so much water
that the Tank overflows.
Avoid splashing water on the Motor, Power Switch, Power Cord, or any other
electrical component. Make sure to stand on a dry, insulated surface such as a
rubber mat while using the Tile Saw.
To avoid accidental injury, always wear heavy duty work gloves when changing
the Saw Blade. Before using the Tile Saw, make sure the Saw Blade is properly
mounted on the Saw Spindle. Make sure the Saw Blade is balanced, and is not
cracked or bent.