SKU 92917 & 93253 For technical questions, please call 1-800-444-3353. Page 7
Connect the air supply to the tool at the Air Plug (83). Set the regulator at the rec-
ommended 70 PSI to 100 PSI, and set not to go over the maximum 100 PSI.
Test the tool by depressing the nose against the workpiece without pulling the Trig-
ger (73). The Tool must not cycle (fire). If it cycles (fires), stop immediately and
have it repaired by a qualified service technician.
Hold the tool away or off of the workpiece. The nose of the tool should return to its
original position. Squeeze the Trigger (73). The tool should not cycle (fire). If the
tool fires, stop immediately and have it repaired by a qualified service technician.
Depress the nose against the workpiece and squeeze the Trigger (73). The tool
must cycle (fire) only once. Release the Trigger and squeeze it again. The tool
must not cycle (fire). With the Trigger held, carefully lift the nailer and press it
against the workpiece again. The tool must not cycle (fire). If it fails to perform
in the manner explained in bold, have it repaired by a qualified service technician.
5.
6.
7.
8.
Loading Coil Nails
ALWAYS WEAR ANSI-APPROVED IMPACT SAFETY GOGGLES WHEN
RELOADING OR DOING ANY OTHER MAINTENANCE ON THIS TOOL.
Other people in the work area must also wear ANSI-approved impact safety
goggles.
Warning! Make sure the Nailer is not attached to the air hose whenever loading
the tool.
NOSE
TRIGGER (73)
AIR PLUG (83)