H.E.R.O. INDUSTRIES 1150GSD MANUAL - “B” VERSION
5
inconvenience and mess of overspray. You are spraying paint, not air, and the paint is driven to the painting
surface in a clean, fan shaped spray which penetrates all cracks and corners. To attain these results, you must
adjust the pressure as low as possible. We recommend that you become familiar with your H.E.R.O. unit.
Discuss with your dealer the useful accessory items he has to offer - various types of tips, extension poles for
hard to reach areas, extra hose, etc. Use of accessory items is often the difference between a good job and an
excellent one!
O P E R A T I N G
INSTRUCTIONS
WARNING
Do not attempt to operate this machine until you have read and understood all safety precautions and
operating instructions. Equipment and chemicals when used improperly can be dangerous.
Your H.E.R.O. airless sprayer has been fully factory tested prior to shipment.
BEFORE STARTING YOUR H.E.R.O. PUMP....
CHECK to ensure that the shipping seal has been removed from under the cap on the hydraulic tank.
Hydraulic tank should be at least 3/4 full of H.E.R.O. LVO hydraulic fluid.
CHECK all fittings and connections in the pump system, hose, and gun to ensure that they are tight.
CHECK to ensure that there is a spray tip in the gun, and that the tip is the correct size for the coating you
are to spray. ( There are various tips available, for each type of coating or configuration. See " Airless Spray
Tip " on page 11 , for proper tip selection.
CHECK to ensure that you have H.E.R.O. strainer bags, H.E.R.O. Wonder Wash, appropriate thinner for
the paint, a waste container, and any other accessories you may require for the job.
READ THIS MANUAL THOROUGHLY.
READ THE HONDA ENGINE MANUAL SUPPLIED WITH THE UNIT. FOLLOW ALL THEIR
RECOMMENDED PROCEDURES FOR “START-UP” AND OPERATION
SETTING UP TO SPRAY
1. Remove unit from shipping carton.
2. Attach intake siphon assembly (ref# 1) to intake elbow (ref# 8). The intake elbow provides a swiveling
connection during assembly only. Two wrenches are required to tighten these fittings. When sufficiently
1997
HYDRAPULSE
“B” VERSION
BEGINNING AT
SERIAL NUMBER
140056