Hitachi DH 50MB Power Hammer User Manual


 
18
English
NOTE: Use HITACHI carbon brush No. indicated in Fig. 21
Replacing carbon brushes:
(For parts name, refer to Fig. 20)
Loosen the tapping screws and remove the brush cap cover. Then, remove the
brush caps and take out the carbon brushes. After replacement, be sure to fasten
the brush caps and fix the brush cap cover firmly using the tapping screws.
6. How to replase grease
This machine is full air-tight construction to protect against dust and to prevent
lubricant leakage. Therefore, the machine can be used without lubrication for
long periods. Replace the grease as described below.
Grease replacement period
After purchase, replace grease after every 6 months of usage. Ask for grease
replacement at the nearest HITACHI Authorized Service Center. Proceed for
replacement of grease.
Grease replenishment
CAUTION: Before replenishing the grease, turn the power off and pull out the
power plug.
(1) Remove the crank case cover and wipe
off the grease inside.
(2) Apply 0.7 oz (20 g) of HITACHI Electric
Hammer Grease A (standard accessory,
contained in tube) to the crank case.
As the tube contains 1 oz (30 g) of
grease, supply 2/3 of the contained
grease.
(3) After replenishing the grease, install the
crank case securely.
Crank Case Cover
Fig. 22
Fig. 21
Wear limit
No. of carbon brush
0.26" (6.5 mm)
0.67" (17 mm)
5
77