1. Clearing a jam
Remove a jammed staple in the following
order:
(1) N5008AB
1 Disconnect air hose.
2 Pull the staple feeder back until it
latches.
Remove all staples. Press the feeder
stop and slide the staple feeder for-
ward.
3 Release the lock lever and open the
blade guide.
4 Remove the jammed staple.
5 Close the blade guide and latch.
6 In case of frequent jam, contact a
Hitachi authorized service center.
(2) N3804AB
1 Disconnect air hose.
2 Pull the staple feeder back until it
latches.
Remove all staples. Press the feeder
stop and slide the staple feeder for-
ward.
3 Using the accessory allen wrench,
rmeove two bolts from the bridge
piece.
Blade
Guide
1 Disconnect
air hose
Lock Lever
Staple
Feeder
Front Nose
Allen Wrench
M5 Hex. Socket Hd. Bolt
Bridge Piece
MAINTENANCE
NOTE:
The information contained in this Manual is designed to assist you in the
safe maintenance of the Stapler.
Some illustrations in this Manual may show details or attachments that
differ from those on your own Stapler.
MAINTENANCE AND INSPECTION
Read section titled SAFETY (pages 4 6).
Disconnect air hose and remove all staples from Stapler when:
1) doing maintenance and inspection; and
2) clearing a jam.