Hobart Welding Products 452 Welder User Manual


 
OM-222 Page 15
3-4. Selecting A Location
1 Lifting Eye
2 Lifting Forks
Use lifting eye or lifting forks to
move unit.
If using lifting forks, extend forks
beyond opposite side of unit.
3 Rating Label (Non CE Models
Only)
Use rating label to determine input
power needs. Label located under
front access door.
4 Plate Label (CE Models Only)
Label located under front access
door.
5 Rating Label (CE Models
Only)
Use rating label to determine input
power needs. Label located on rear
access door (see Section 2-5).
6 Line Disconnect Device
Locate unit near correct input pow-
er supply.
Y Special installation may be
required where gasoline or
volatile liquids are present
see NEC Article 511 or CEC
Section 20.
3
6
18 in
(460 mm)
18 in
(460 mm)
OR
1
2
Movement
Location And Airflow
4
5
3-5. Dimensions And Weights
Dimensions
C
Height 27-1/4 in (692 mm)
D
E
Width 22-1/4 in (565 mm)
4 Holes
Depth* 35-3/4 in (908 mm)
A** 35 in (889 mm)
B*** 1-1/4 in (32 mm)
C 21-1/8 in (537 mm)
D 1-1/8 in (29 mm)
A
E 7/16 in (11 mm) Dia
*300 Amp Model = 28-1/4 in (718 mm)
**300 Amp Model = 27-1/2 in (699 mm)
***300 Amp Model = 3/4 in (19 mm)
Weight
300 Amp 352 lb (160 kg)
450 Amp 404 lb (183 kg)
B
801 530
650 Amp 505 lb (299 kg)