. A complete Parts List is available at www.HobartWelders.com
OM-926 Page 10
SECTION 4 − INSTALLATION
4-1. Specifications
50/60 Hz
Amperes Input at
Rated Load
Output 50/60 Hz
Rated
Output
Type of
Output
Plasma
Gas
Rated
Cutting
Capacity
Maximum
Open-Circui
t
Voltage DC
208 V 230 V KVA KW
Output
Output
Gas
Capacity
Voltage DC
Single-
Phase
33 30 6.8 6.7
40 A @ 140
Volts DC,
50% Duty
Cycle
Direct
Current,
Straight
Polarity
(DCEN)
Air Or
Nitrogen
Only
0.5 in
(12.7 mm)
At 16 IPM
260
4-2. Specifications For Torch
Air-cooled torch for plasma arc cutting (PAC)
50% duty cycle
Safety interlock devices disable power source
Safety trigger guard
Cutting capacity: see Section 4-1
4-3. Duty Cycle And Overheating
Duty Cycle is percentage of 10
minutes that unit can cut at rated
load without overheating.
If unit overheats, output stops,
temperature status light
illuminates, and cooling fan runs.
Wait fifteen minutes for unit to cool
or temperature light to go off.
Reduce amperage or duty cycle
before cutting or gouging.
Y Exceeding duty cycle can
damage unit and void
warranty.
Overheating
sduty1 5/95 / Ref. 803 219
For Units Connected to a 208 Volt Circuit or a 230 Volt Circuit:
50% Duty Cycle At 40 amperes, 140 volts dc (typical cutting)
0
15
Minutes
A
OR
Reduce Duty Cycle
5 Minutes Cutting 5 Minutes Resting
4-4. Torch Dimensions And Weight
Ref. 801 397-A
3.5 lb (1.6 kg) With 25 ft (7.6 m) Cable
1 in (25 mm)
8-3/8 in
(213 mm)
1-3/8 in (35 mm)