Hobart Welding Products OM-950 Welder User Manual


 
OM-950 Page 10
SECTION 4 INSTALLATION
4-1. Specifications
AC/DC Models
Mode
Rated Welding
Out
p
ut
Amperage
Ran
g
e
Maximum
Open-
Circuit
Amperes Input at Rated Load
Output 50 Or 60 Hz,
Single-Phase
Weight
Output
Range
Circuit
Voltage
230 V
AC
225 A @ 25 Volts AC,
20% Duty Cycle @ 60 Hz;
15% Duty Cycle @ 50 Hz
Low: 30 150
High: 40 235
80 VAC
47 5
104 lb
DC
150 A @ 25 Volts DC,
20% Duty Cycle @ 60 Hz;
15% Duty Cycle @ 50 Hz
30 160 80 VDC
47.5
2.3*
104 lb
(47 kg)
Overall Dimensions
Height: 18-3/4 in (476 mm); Width: 12-3/4 in (323 mm); Depth: 17-1/2 in (445 mm)
*While idling
AC Models
Rated Welding Output
Amperage
Ran
g
e
Max Open-
Circuit
Voltage
Amperes Input at Rated Load
Output 50 Or 60 Hz,
Single-Phase
Weight
Range
Voltage
230 V
225 A @ 25 Volts AC, 20% Duty Cycle @ 60
Hz;
15% Duty Cycle @ 50 Hz
Low: 30 150A
High: 40 235A
80 VAC
47.5
2.3*
85 lb
(39 kg)
Overall Dimensions
Height: 18-3/4 in (476 mm); Width: 12-3/4 in (323 mm); Depth: 17-1/2 in (445 mm)
*While idling