Hobart Welding Products OM-950 Welder User Manual


 
OM-950 Page 13
B. For AC Models
193 508
The volt-ampere curves show the
minimum and maximum voltage
and amperage output capabilities.
Curves of other settings fall be-
tween the curves shown.
0
10
20
30
40
50
60
70
80
90
0 50 100 150 200 250 300
AC Amperes
AC Volts
A=LOW RANGE
B=HIGH RANGE
A
A
BB
For 235A Models
4-4. Selecting A Location
804 292-A
1 Rating Label (See Section
3-2)
Locate unit near correct input
power.
Y Special installation may be
required where gasoline or
volatile liquids are present
see NEC Article 511 or CEC
Section 20.
18 in (457 mm) for airflow
1