Ingersoll-Rand WG068A-F4 Impact Driver User Manual


 
M35
41
MAINTENANCE SECTION
TROUBLESHOOTING GUIDE
Double
I
Probable Cause
Low power
Motor will not run
Tool will not impact
Dirty Inlet Bushing or Air
Strainer Screen and/or Exhaust
Using a suitable cleaning solution, in a well
ventilated area, clean Air Strainer Screen, Inlet
Silencer Bushing and Exhaust Silencer.
Worn or broken Vanes
Worn or broken Cylinder and/or
scored End Plates-
Dirty motor parts
Improper positioning of Reverse
Valve
Incorrect assembly of motor
Insufficient lubricant in the
impact mechanism
Broken or worn impact
mechanism parts
Impact mechanism not assembled
correctly
Solution
Replace complete set of Vanes.
Examine Cylinder and replace it if it is worn or
broken or if bore is scored or wavy. Replace End
Plates if they are scored.
Disassemble tool and clean all parts with a
suitable cleaning solution, in a well-ventilated area.
Reassemble tool as instructed in this manual.
Make certain that Reverse Valve is fully
engaged to the left or right.
Disassemble motor and replace worn or broken
parts and reassemble as instructed.
Remove Hammer Case Assembly and lubricate
impact mechanism.
Remove Hammer Case and examine impact
mechanism parts. Replace any worn or broken
parts.
Refer to Assembly of the Impact Mechanism.
SAVE THESE INSTRUCTIONS. DO NOT DESTROY.
9