Jet Tools PDS-12CS Cordless Sander User Manual


 
6
230 Volt Operation
If 230V, single phase operation is desired, the following instructions must be followed:
1. Disconnect the machine from the power source.
2. This POWERMATIC sander is supplied with four motor leads that are connected for 115V operation,
as shown in Figure A. Reconnect these four motor leads for 230V operation, as shown in Figure B.
3. The 115V attachment plug (A), supplied with the sander, must be replaced with a UL/CSA listed plug
suitable for 230V operation (D). Contact your local Authorized POWERMATIC Service Center or
qualified electrician for proper procedures to install the plug. The sander must comply with all local
and national codes after the 230 volt plug is installed.
4. The sander with a 230 volt plug should only be connected to an outlet having the same configuration
(D). No adapter is available or should be used with the 230 volt plug.
Important: In all cases (115 or 230 volts), make certain the receptacle in question is properly grounded.
If you are not sure, have a registered electrician check the receptacle.