Jet Tools HVBS-56M Saw User Manual


 
8
4. Remove two screws (D, Fig. 7) and plate (E,
Fig. 7).
5. Guide blade through slot in table (A, Fig. 8)
and fasten table with two screws (B, Fig. 8).
6. Fasten support bracket to underside of table
using screw (C, Fig. 8) and hex nut.
7. Tighten bolt (B, Fig 7).
Electrical Connections
WARNING
All electrical connections must be completed
by a qualified electrician.
Failure to comply may cause serious injury!
The HVBS-463 bandsaw is rated at 115/230V
and comes from the factory prewired 115V.
To switch to 230V operation, follow the wiring
diagram found on the inside of the motor
junction box. The plug on the end will have to
be replaced with a plug that is rated at 230V.
This bandsaw is designed for use on a circuit
with an outlet that looks like (A, Fig. 9). The
bandsaw has a grounding prong as illustrated in
(B, Fig. 9). A temporary adapter (C, Fig. 9) may
be used to connect the plug to a two pole
receptacle (D, Fig. 9) if a properly grounded
outlet is not available. The temporary adapter
should only be used until a properly grounded
outlet can be installed by a qualified electrician.
The green colored lug must be securely
fastened to the cover plate screw.
Before hooking up to the power source, be sure
the switch is in the off position.