John Deere HR1-20E Air Compressor User Manual


 
Electric Air Compressor Manual 15
MAINTENANCE INSTRUCTIONS:
Read the instruction manual before performing maintenance. The following procedures
must be performed when stopping the air compressor for maintenance or service.
1. Turn off air compressor
2. Disconnect power cord from the power source.
3. Open all drains.
4. Wait for the air compressor to cool before starting service.
OPERATING INSTRUCTIONS
WARNING
RISK OF BODILY INJURY!
Never assume the air com-
pressor is safe to work on just
because it is not operating. It
could restart at any time!
*The pump oil must be changed after the rst 50 hours of operation and every 200 hours or 3 months, whichever
comes rst. In harsh environments, maintenance must be performed on a more accelerated schedule.
Every 2 years, an Authorized Service Technician should check the check valve, intake valves and delivery valves.
MAINTENANCE CHART
AC Ele. Maintenance Chart
MAINTENANCE CHART
PROCEDURE DAILY WEEKLY MONTHLY 200 HOURS
Check pump oil level X
Oil leak inspection X
Drain condensation in air tank (s) X
Inspect guards/covers X
Check for unusual noise/vibration X
Check for air leaks X
Clean exterior of compressor X
Inspect air filter X
Check safety relief valve X
Change pump oil * X
Replace air filter X