5
Start-up
Leica DISTO™ D3 760498a en
EN
F
E
P
Labelling
Position of the product label see last page!
Start-up
Inserting/replacing batteries
See figure {A}
1 Remove battery compartment lid and attach
handstrap.
2 Insert batteries, observing correct polarity.
3 Close the battery compartment again. Replace
the batteries when the symbol flashes perma-
nently in the display.
)
Use alkaline batteries only.
)
Remove the batteries before any long period
of non-use to avoid the danger of corrosion.
Multifunctional endpiece
See figure {B}
The instrument can be adapted for the following
measuring situations:
• For measurements from an edge, fold out the
positioning bracket until it first locks in place. See
figure {C}.
• For measurements from a corner, open the posi-
tioning bracket until it locks in place, then push
the positioning bracket lightly to the right to fold
it out fully. See figure {D}.
Laser Radiation
Do not stare into the beam
Laser class 2
acc. IEC 60825-1:2007
Maximum radiant power: <1mW
Emitted wavelength: 620-690nm
Beam divergence: 0.16 x 0.6 mrad
Pulse duration: 1 x 10
-9
s