LG Electronics 42LY770M Saw User Manual


 
41
206-4271
Installer Menu (Cont.)
023 - CAPTION LOCK
If set to 0, captions are OFF when the TV is turned ON. Set to 1
to use the caption setting congured before the TV was turned
OFF when the TV is turned ON.
025 - FUNCTION PRE (Function Preview)
Set to 1 to allow access to the Channel Preview/Banks Setup
Menu via the CH PREVIEW key on Installer Remote. Set to 0 to
disable access to the Channel Preview/Banks Setup Menu.
027 - HOSPITAL MODE
Set according to the speaker selection, the pillow speaker code/
supply voltage and the hospital IR code. If using a Pro:Centric
pillow speaker, select one of the Zenith codes in accordance with
the desired speaker selection. See table below.
Value Speaker
Pillow Speaker
Code/Voltage
Hospital IR Code
000 Determined by
item 020 setting
Zenith (+12v) Determined by item
020 setting
001 Pillow Only Zenith (+12v) Zenith Bed #1
002 Pillow Only Zenith (+12v) Zenith Bed #2
017 Pillow Only Philips (+5v) Zenith Bed #1
018 Pillow Only Philips (+5v) Zenith Bed #2
033 Pillow Only RCA (-5v) Zenith Bed #1
034 Pillow Only RCA (-5v) Zenith Bed #2
065 TV Only Zenith (+12v) Zenith Bed #1
066 TV Only Zenith (+12v) Zenith Bed #2
081 TV Only Philips (+5v) Zenith Bed #1
082 TV Only Philips (+5v) Zenith Bed #2
097 TV Only RCA (-5v) Zenith Bed #1
098 TV Only RCA (-5v) Zenith Bed #2
129 Both Pillow & TV Zenith (+12v) Zenith Bed #1
130 Both Pillow & TV Zenith (+12v) Zenith Bed #2
145 Both Pillow & TV Philips (+5v) Zenith Bed #1
146 Both Pillow & TV Philips (+5v) Zenith Bed #2
161 Both Pillow & TV RCA (-5v) Zenith Bed #1
162 Both Pillow & TV RCA (-5v) Zenith Bed #2
254 TV Only Disabled (0v) Zenith Bed #2
When Hospital Mode is enabled and the TV is in Pass-through
Mode, channel banks are also available. Refer to channel banks
information in this document for further details.
Channel banks are not supported if Hospital Mode is set to 0 or on
TVs that are congured for FTG Mode operation.
When Hospital Mode is set to 0 (disabled), both the IR code
that will control the TV and the speaker selection depend on the
Installer Menu item 020 FEATURE LEVEL setting.
Note: The default setting (254) is not selectable in the Installer
Menu. If you ever need to restore the default setting, you must set
item 117 FACT DEFAULT to 1 to reload the factory default settings.
See item 117 description for further information.
Note: In the Installer Menu, an informational code is displayed
at the right of each Hospital Mode value. Each code consists of
three characters. The rst character—T, P, or B—identies the
speaker: TV, Pillow, or Both. The second character—Z, P, R,
or D—identies the pillow speaker code: Zenith, Philips, RCA, or
Disabled. The third character—1 or 2—identies the bed number.
In the table on the previous page, each bolded character represents
an element of the Hospital Mode code.
028 - CH. OVERIDE (Channel Override)
Applicable for Pass-through Mode only. If set to 1, users can select
channels either with Channel Up/Down or by direct keypad entry.
This setting also allows full access to channel settings in the TV
setup menus (i.e., channels may be added or removed from the
channel lineup, channel labels and icons may be edited, etc.).
If set to 0, the channel lineup is locked. That is, user access to
channel settings in the TV setup menus is restricted, and users can
only tune to the channels that are included in the channel lineup.
Also, in this case, users can only select channels using Channel
Up/Down; direct keypad entry is not available.
029 - OLD OCV (On Command Video™)
Set to 1 to remap the PTC’s direct tune channels for Aux inputs
from 13x to 9x. This allows 2-digit only tuning systems (i.e.,
legacy OCV) to direct tune Aux inputs. See also Reference sec-
tion, “TV Aux Input Conguration.”
030 - ACK MASK
MPI Communication Parameter. When set to 1, enables ACK
feature of MPI.
031 - POLL RATE
MPI Communication Parameter. Selects poll rate for MPI. Step
size of 16 ms. Changing from default may affect communication
via MPI.
032 - TIMING PULSE
MPI Communication Parameter. Sets baud rate for MPI. Step size
of 4.3 uS. Changing from default may affect communication via
MPI.
035 - HDMI1 ENABLE
Set to 1 to enable HDMI 1 input in DTV Mode. Set to 2 to enable
HDMI 1 input in PC Mode. Set to 0 to disable display panel HDMI
1 input.
039 - REAR AUX EN. (Rear Aux Enable)
Set to 1 to enable display panel rear Aux (Video 1) input. Set to 0
to disable display panel rear Aux (Video 1) input.