Lincoln Electric 3200HD Welding System User Manual


 
A-1
WELD PAK 3200HD
A-1
Fuse or
Output Mode Input Voltage Breaker Size
1
Input Amps Power Cord Extension Cord
Three Conductor
#14 AWG
(2.1 mm
2
) or Larger
RATED 120V/60Hz 20 Amp 20 15 Amp, 125V,
Up to 25 Ft. (7.6 mm)
Three Prong Plug Three Conductor
(NEMA Type 5-15P) #12 AWG
(3.3 mm
2
) or Larger
Up to 50 Ft. (15.2 mm)
INSTALLATION
TECHNICAL SPECIFICATIONS – WELD-PAK 3200HD
INPUT – SINGLE PHASE ONLY
RATED OUTPUT
OUTPUT
RECOMMENDED INPUT CABLE AND FUSE SIZES
Height Width Depth Weight
12.0 in 9.75 in 16.5 in 48 Ibs
305 mm 248 mm 419 mm 21.8 kg
PHYSICAL DIMENSIONS
Standard Voltage/Frequency Input Current
120V/60Hz 20 Amps - Rated Output
Duty
Cycle Amps Volts at Rated Amperes
20% Duty Cycle 90 19
Welding Current Range Maximum-Open Circuit Voltage 50 - 300 in/min
25-135 Amps 29V (1.3 - 7.6 m/min)
1
If connected to a circuit protected by fuses use Time Delay Fuse marked “D”.