Lincoln Electric CV-300 Welding Consumables User Manual


 
F-6
DIAGRAMS
F-6
CV-300
CV POWER SOURCE TO AN LN-25 / K444-1
Only qualified persons should install, use or
service this machine.
using the disconnect switch at the fuse box
WARNING
Turn off input power to the Welding Power Source
Before connecting the wire feeder.
ELECTRIC
SHOCK
CAN KILL
N.A. WELDING CABLE MUST BE SIZED FOR CURRENT AND DUTY CYCLE OF APPLICATION.
N.B. DIAGRAM SHOWS ELECTRODE POSITIVE. TO CHANGE POLARITY, TURN POWER "OFF",
ELECTRODE CABLE
-
+
14 PIN
AMPHENOL
POWER SOURCE
CV/CV-I
TO WORK
LN-25
WIRE FEEDER
OPTIONAL
K484 JUMPER
PLUG
OPTIONAL K864 REMOTE
CONTROL ADAPTER
WITH K444-1 OPTION
N.D.N.D.
N.C.
N.C. CONNECT THE K484 JUMPER PLUG TO THE 14 PIN RECEPTACLE OF THE
K864 REMOTE CONTROL ADAPTER. CONNECT THE 6 PIN PLUG FROM THE
LN-25 (WITH K444-1 OPTION) TO THE 6 PIN RECEPTACLE OF THE K864
N.D. THE POWER SOURCE TERMINALS ARE ALWAYS "HOT" WHEN THE K484 JUMPER
PLUG KIT IS INSTALLED.
REVERSE ELECTRODE AND WORK CABLES AT POWER SOURCE, SWITCH LN-25 POLARITY SWITCH.
REMOTE CONTROL ADAPTER. SWITCH THE POWER SOURCE "LOCAL/REMOTE" SWITCH TO REMOTE.
CLEVELAND, OHIO U.S.A.
S20663
CV/CV-I POWER SOURCE TO LN-25 WITH K444-1 OPTION CONNECTION DIAGRAM
6-18-93