Lincoln Electric CV320-I Welder User Manual


 
IMA 574B CV320-I Page 3
5. a. Use only compressed gas cylinders containing the
correct shielding gas for the process used and
properly operating regulators, designed for the gas
and pressure used. All hoses, fittings, etc. should be
suitable for the application and maintained in good
condition.
b. Always keep cylinders in an upright position and
securely chained to an undercarriage or fixed
support.
c. Cylinders should be located :
Away from areas where they may be struck or
subjected to physical damage.
A safe distance from arc welding or cutting
operations and any other source of heat, sparks or
flame.
d. Never allow the electrode, electrode holder, or any
other electrically “hot” parts to touch a cylinder.
e. Keep your head and face away from the cylinder
valve outlet when opening the cylinder valve.
f. Valve protection caps should always be in place and
hand-tight except when the cylinder is in use or
connected for use.
g. Read and follow the instructions on compressed gas
cylinders and associated equipment, and AS 2030
Parts 1 & 2.
6. a. Turn off input power using the disconnect switch at
the fuse box before working on the equipment.
b. Install equipment in accordance with the SAA Wiring
Rules, all local codes and the manufacturer’s
recommendations.
c. Ground the equipment in accordance with the SAA
Wiring Rules and the manufacturer’s
recommendations.
7. a.Turn the engine off before troubleshooting and
maintenance work unless the maintenance
work requires it to be running.
b.Operate engines in open, well ventilated areas
or vent the engine exhaust fumes outdoors.
c. Do not add fuel near an open flame, welding
arc or when the engine is running. Stop the
engine and allow it to cool before refuelling to
prevent spilled fuel from vaporizing on contact
with hot engine parts and igniting. Do not spill
fuel when filling tank. If fuel is spilled, wipe it up
and do not start engine until fumes have been
eliminated.
d.Keep all equipment, safety guards, covers
and devices in position and in good repair.
Keep hands, hair, clothing and tools away
from V-belts, gears, fans and all other
moving parts when starting, operating or
repairing equipment.
e.In some cases it may be necessary to remove
safety guards to perform required
maintenance. Remove guards only when
necessary and replace them when the
maintenance requiring their removal is
complete. Always use the greatest care when
working near moving parts.
f. Do not put your hands near the engine fan.
Do not attempt to override the governor or
idler by pushing on the throttle control rods
while the engine is running.
g.To prevent accidentally starting petrol engines
while turning the engine or welding generator
during maintenance work, disconnect the
spark plug wires, distributor cap or magneto
wire as appropriate.
h.To avoid scalding do not remove the radiator
pressure cap when the engine is hot.
CYLINDER may explode if
damaged
FOR ELECTRICALLY
powered equipment
FOR ENGINE powered
equipment
HAVE ALL INSTALLATIONS, OPERATION, MAINTENANCE AND REPAIR WORK PERFORMED BY QUALIFIED PEOPLE
HOW TO ORDER REPLACEMENT PARTS
To ensure that you receive the correct replacement part the following procedure should be followed:
1. Quote Serial Number and Code Number.
2. Quote the Description, Item Number and Parts List Number of the desired part. When ordering parts for items
carrying brand names of other companies, such as fan motors, drive shafts, etc., be sure to include the other
company’s name and part number and other relevant information.
3. Should the primary cord be damaged, a special cord is required, and is available from Lincoln.
4. Parts should be ordered from Lincoln’s nearest authorised Field Service Shop. (The “Lincoln
Service Directory” listing these shops geographically is available on request.)
NOTE: “Hardware” in the Lincoln Parts Lists are not Lincoln stock items but can be obtained via the Field Service Shop network.
Component parts of assemblies such as stator coils or armature coils, etc., which require electrical testing or locating fixtures are
not considered replaceable items. This is to ensure that the customer receives parts which will keep the welder in the best
operating condition.
For more detailed information it is strongly recommended that you purchase a copy of “Safety in Welding and Cutting - ANSI
Standard Z 49.1” and WTIA Technical Note 7. All WTIA publications and ANSI/AWS Standards are available from the Welding
Technology Institute of Australia, P.O. Box 6165, Silverwater NSW 2128. For copies of various Australian Standards contact your
local S.A.A. office.