Lincoln Electric IM822 Welding System User Manual


 
A-1
MIG PAK HD
A-1
Fuse or
Output Mode Input Voltage Breaker Size
1
Input Amps Power Cord Extension Cord
AT
RATED 120V/60Hz 20 Amp 20 15 Amp, 125V, Three Conductor
OUTPUT Three Prong Plug #12 AWG
(NEMA Type 5-15P) (3.3 mm
2
) or Larger
Up to 50 Ft. (15.2 mm)
INSTALLATION
TECHNICAL SPECIFICATIONS – MIG PAK HD
INPUT – SINGLE PHASE ONLY
RATED OUTPUT
OUTPUT RANGE
RECOMMENDED INPUT CABLE AND FUSE SIZES
Height Width Depth Weight
12.8 in 8.8 in 18 in 46 Ibs
325 mm 224 mm 457 mm 20.9 kg
PHYSICAL DIMENSIONS
Standard Voltage/Frequency Input Current
120V/60Hz 20 Amps @ Rated Output
Duty
Cycle Amps Volts at Rated Amperes
20% Duty Cycle 70 17
Welding Current Range Maximum-Open Circuit Voltage No Load 0 - 450 in/min
DC OUTPUT: 35-88 Amps 29V (0 - 17.7 mm/min)
While welding 0-300 in/min.
(0-11.8 mm/min.)
1
If connected to a circuit protected by fuses use Time Delay Fuse marked “D”.