Lincoln Electric IM892-C Welder User Manual


 
B-25
OPERATION
B-25
POWER FEED™ 25M
SET-UP FEATURES MENU
(See Figure B.17b and B.17c for specific Codes)
1. To access the set-up menu, press the Right and
Left buttons of the MSP4 panel simultaneously.
Note that the set-up menu cannot be accessed if
the system is welding, or if there is a fault (The sta-
tus LED is not solid green).
Change the value of the blinking parameter by rotat-
ing the SET knob.
2. After changing a parameter it is necessary to press
the Right hand button to save the new setting.
Pressing the Left button will cancel the change.
3. To exit the set-up menu at any time, press the
Right and Left buttons of the MSP4 panel simulta-
neously. Alternately, 1 minute of inactivity will also
exit the set-up menu.
The Setup Menu gives access to the Setup Configuration. Stored in the setup configuration are user parameters
that generally only need to be set at installation. The parameters are grouped as shown in the following table.
SETUP MENU FEATURES
PARAMETER
P.1 through P.99
P.101 through P.199
P.501 through P.599
DEFINITION
Unsecured Parameters (always adjustable)
Diagnostic Parameters (always read only)
Secured Parameters (only accessible through a p.c. or palm application)
LED
Indicator
Mode Select
Panel (MSP4)
Right
button
SET Knob
Left
buttom
LED
Indicator
Mode Select
Panel (MSP4)
Right
button
SET Knob
Left
buttom
FIGURE B.17b - SETUP MENU
(Only parameters below can be accessed in Code 11313)
P.0 P.7 P.100 thru P.107
P.1 P.8
P.2 P.11
P.3 P.12
P.4 P.13
P.5 P.80
P.6 P.99
FIGURE B.17c - SETUP MENU
(All parameters can be accessed in Code 11456 and higher)