Miller Electric 600 X Welder User Manual


 
OM-4428 Page 43
9-2. Routine Maintenance (Deutz F4L2011-Powered Units)
! Stop engine before maintaining.
. See Engine Manual and Maintenance Label
for important start-up, service, and storage
information. Service engine more often if
used in severe conditions.
Recycle engine
fluids.
n = Check Z = Change ~ = Clean l = Replace
* To be done by Factory Authorized Service Agent
Reference
Every
8
Hours
FUEL
WATER
Section 5-8
n Fuel/Water Separator n Fuel Level n Oil Level ~ Oil, Fuel Spills
Every
50
Hours
~ Weld Terminals
Every
100
Hours
Section 9-4
~ Battery Terminals n Air Cleaner Hoses n L’élément du filtre à air
Every
250
Hours
1/2 in.
(13 mm)
Engine
Manual,
Section 9-5
l Unreadable Labels n Fan Belt Tension ~ Cooling System n~Spark Arrestor
Every
500
Hours
nl Weld Cables
Every
1000
Hours
Section 5-8,
9-3, 9-7 and
Engine
Manual
Z Oil Z Oil Filter Z FuelFilter
Manual
OR
SLUDGE
FUEL
n~ Slip Rings*
nl Brushes*
~ Inside Unit nValve Clearance* ~ Drain Sludge
Every
3000
Hours
~ Injectors*
Every
6000
Hours
or 5
Years
nl Engine Timing Belt