OM-4428 Page 51
10-2. Routine Maintenance (Deutz F3L912-Powered Units)
! Stop engine before maintaining.
. See Engine Manual and Maintenance Label
for important start-up, service, and storage
information. Service engine more often if
used in severe conditions.
Recycle engine
fluids.
n = Check Z = Change ~ = Clean l = Replace
* To be done by Factory Authorized Service Agent
Reference
Every
8
Hours
FUEL
WATER
Section 5-8,
n Fuel/Water Separator n Fuel Level n Oil Level ~ Oil, Fuel Spills
Every
50
Hours
~ Weld Terminals
Every
100
Hours
Section
10-4
~ Battery Terminals n Air Cleaner Hoses n Air Cleaner Element
Every
250
Hours
1/2 in.
(13 mm)
Engine
Manual,
Section
10-5
l Unreadable Labels n Fan Belt Tension ~ Cooling System n~Spark Arrestor
Every
500
Hours
nl Weld Cables Z Oil Z Oil Filter
Every
1000
Hours
OR
SLUDGE
FUEL
Section 5-8,
10-3 and
Engine
Manual
n~ Slip Rings*
nl Brushes*
~ Inside Unit Z FuelFilter ~ Drain Sludge
nValve Clearance*
Every
3000
Hours
~ Injectors*
Every
6000
Hours
or 5
Years