BLW-400SSW-WELDER/AC GENERATOR PARTS & OPERATION MANUAL REV. #1 (06/15/01) PAGE 23
BLW-400SSW CONTROLS AND INDICATORS
Figure 6 shows the location of the controls and indicators. The
functions of each control or indicator is described below.
1. DC Current Selector/Single-Use to select current when
using welder for single operator.
2. Current Range Selector- Use to select for single or dual
welding operators.
3. DC Current Selector/Dual- Use to select current when
using welder for dual operators.
4. AC Voltmeter-Indicates the output of total voltage with
welder and/or generator.
5. AC Circuit Breaker- This 53 amp main circuit breaker will
shut down current if welder/generator is overloaded.
6. Engine Indicator Lamps- Lights red when the following
conditions occur:
7. Preheat Indicator-Indicates the engine is warmed up for
welding/adding load.
8. Ignition Switch With key inserted turn clockwise to start
engine.
9. Hour Meter Indicates number of hours machine has
been in use or hours engine was run.
10. Idle Switch- Turn on for rpms to automatically adjust rpms
when a load is added.
11. Fuel Gauge Indicates the amount of fuel in the fuel tank.
!
Low Oil Pressure
!
High Water Temperature
!
Electrical System Is Not Charging Properly
Table of Contents