Omega Engineering FP-6000 Stud Sensor User Manual


 
8
Once the correct dimensions are calculated and
recorded, the sensor can be installed in the fitting.
The Standard and Hot-Tap versions require
substantially different procedures.
3.6 Standard Installation
1. Thread one hex nut onto each of the three
threaded rods included in package. Install
threaded rod with a lock-washer onto the brass
sensor nut. Secure rods in place by tightening
each hex nut against the brass sensor nut.
2. Thread one jam nut and lower hex nut onto
each stud so that the top surface of each nut is at
the proper "H" dimension for your pipe. Secure
each hex nut with a jam nut.
3. Insert the flow sensor into the brass sensor nut,
making sure the alignment hole on the sensor
flange is pointing downstream.
brass sensor nut
hex nut
lock washer
Step 1
process pipe
lower hex nuts
(3/16 x 1/4-20)
jam nuts
(5/32 x 1/4-20)
"H"
brass sensor nut
hex nut and lock washer
jam nut, 1'st
Step 2
lower hex nut, 2nd