Oneida Air Systems Super Dust Gorilla Dust Collector User Manual


 
VIII. Filter Assembly
9
2HP Super Dust Gorilla Owners Manual
O.A.S. 2007
c
Note: Do not return exhaust air to the shop unless filter media is added.
External 39 Filter Assembly
1. Attach cartridge with hardware provided making sure
gasket is attached. See Fig. 1
2. If Filter requires additional support. Use the plate at the
top of the filter to support the filter assembly.
Note: If filter cartridge is located away from the cyclone
and motor, additional square-to-round connectors and pipe
can be purchased.
*Silencer Included.
For Filter cleaning instructions and
Dust Pan clipping instructions, see pg. 11.
Caution:
If exhaust air is vented outside you must provide make up / return air.
Flue gases (carbon monoxide) can be drawn into the shop from furnaces,
water heaters or other appliances.
1. Exhaust air to exterior of building.
Mount directly at the hole in exterior
wall or use a square-to-round transition
and ductwork to vent air to exterior.
No Filter Assembly
* Exhaust Diverter -
Can be used either
up or down
Option -
* Only usable on No Filter.
Caution: Rotating blades! Keep hands clear. Keep
people away from exhaust.
GORILLA
The
TM
GORILLA
The
TM
Fig. 1
Gasket
Material
(4) 3/8 x 1 Bolts
(8) Washers
(4) Serrated Nuts
Before attaching filter, you must first
carefully pull foam silencer on to end of
plenum, pushing black plastic end against
flange plate. It is a tight fit.
Dust Bin
Dust Pan
Clips (3)
Silencer
Filter
Rod
Brace
Washer
Wing Nut