Oneida Air Systems Super Dust Gorilla Dust Collector User Manual


 
III. General Specifications & Fan Performance Curves
2HP Super Dust Gorilla Owners Manual
O.A.S. 2007
c
4
- Sleeve kit adds 7 (4 is minimum)
- 35 gal. bin is 22 dia. x 22.5 h / 55 gal. bin is 22 dia. x 35.5 h
- Several Filter Options Available- Galvanized steel construction
- The collector can be hung on the wall, from the ceiling, or free standing support using
the 10 ga. angle iron ring at the top of the cone.
(See assembly instructions)
2.0 hp
Height without
Dust Bin
Cyclone
Diameter
Inlet
Diameter
Weight without
Dust Bin
TEFC
Motors
Class F
115/230v
23/11.5 amps
1.15 Service Factor
63 21 7
Approx. Wt.
122 lbs.
w/o drum or filter
Static pressure and volume together determine
a fans performance. Several factors, such as
layout of ductwork and diameter of openings,
can affect a fans performance.
2hp Super Dust Gorilla System
Industrial Baldor TEFC 2hp motor*
115/230v - 23/11.5 amps / 1.15 Service Factor
Full 16 gauge galvanized cyclone & 11 ga. fan housing
7 dia. inlet / 8 rectangular outlet
14.25 dia. x 4 wide cast aluminum fan wheel
back inclined non-sparking, non-ferrous dynamic, two-planed
balanced to ISO 6.3 specifications.
Sound 78 - 79dB @ 10 with Built-in Silencer and Filter
95 Sq. Ft. Filter Media / Spun-Bonded
2hp Super Dust Gorilla CFM vs. SP Curve*
9
8
7
6
5
4
3
2
0
Static Pressure at Cyclone Inlet
CFM
0 200 400 600 1000800
10
1400 1600
6.3
1200
10.65
9.4
4.3
11
8.25
3
2.3
1422 cfm @
2.3 SP w/c
w/o filter.
Vented outside.
- Without Filter
- With Filter
*Fan curves vary slightly with different filter packages.
1349 cfm @ 2.3
SP w/c w/ filter.
FCS133900
1422 CFM @ 2.3 SP w/c w/o filter
*
* Note: Motor Starter supplied
with system is for 220v only.