MATE-DISPLAYED MX60 STATUS SETPT (SETPOINT) Screens
Press the  rst two soft keys simultaneously to return
to the MAIN Menu or press <STATUS> and then
press <MAIN> on the STATUS screen.
MX SETP(OINT) Screens
Absorb: displays the voltage that initiates and maintains the Absorb cycle
Float: displays the voltage that begins the Float cycle and is maintained during this cycle
STATUS/MX/SETPT----P00
Absorb 28.8 VDC
DOWN STATUS PORT
STATUS/MX/SETPT---P00
Float 27.2 VDC
DOWN UP TOP PORT
STATUS/MX/METER------