Outback Power Systems Systems Battery Charger User Manual


 
2005 OutBack Power Systems Inc.
l
28
13
PS1 Specifications Sealed Models Vented Models
PS1-2500 PS1-3000
Continuous Power Rating At 40° C 2500 VA 3000 VA
At 25° C 3000 VA 3600 VA
AC Voltage / Frequency Output 120 VAC 60 Hz 120 VAC 60 Hz
AC Input Current Maximum AC Transfer Switch 50 amps AC 50 amps AC
Battery Charger 16 amps AC with automatic back-off 20 amps AC with automatic back-off
Maximum AC Surge Current Peak (1 millisecond) 70 amps AC 70 amps AC
RMS (5 seconds) 50 amps AC 50 amps AC
Maximum PV Array Wattage 3300 watts DC stc rating 3300 watts DC stc rating
PV Open Circuit Voltage Maximum 150 VDC 150 VDC
MPPT Input Voltage Range 44 to 135 VDC 44 to 135 VDC
PV Array Ground Fault Protection Standard - 80 amp DC Standard - 80 amp DC
Inverter Efficiency Typical 91% (not CEC Certified) 91% (CEC Certified)
Peak 93% 93%
MPPT Efficiency 98% 98%
Overall System Efficiency Typical 89% 89%
Peak 92% 92%
Battery Voltage - Nominal 48 VDC 48 VDC
Minimum / maximum operating range 40 to 60 VDC 40 to 60 VDC
Battery Charge Rate Inverter 35 amps DC 45 amps DC
MX60 60 amps DC 60 amps DC
AC Output Voltage Regulation Typical 5% 5%
Nominal 120 VAC 120 VAC
AC Output Current Inverting 25.0 amps AC 30.0 amps AC
Selling 20.8 amps AC 25.0 amps AC
Total Harmonic Distortion Inverting 2% VAC THD 2% VAC THD
Selling < 5% current THD per UL1741 conditions < 5% current THD per UL1741 conditions
AC Transfer Switch Speed Typical < 16 Milliseconds < 16 Milliseconds
Battery Temperature Sensor Included Included
Operating Temperature Range -40° C to 60° C (power derated above 25° C) -40° C to 60° C (power derated above 25° C)
Recommended Minimum Energy Storage 4 kWHRS at 80% discharge 4 kWHRS at 80% discharge
Recommended Batteries Four AGM type 31 or type 27 sealed VRLA Four AGM type 31 or type 27 sealed VRLA
Communications Optional MATE system display with RS232 port Optional MATE system display with RS232 port
Enclosure Materials Powder coated aluminum, stainless steel hardware Powder coated aluminum, stainless steel hardware
Mounting Wall mount, 16 on center studs Wall mount, 16" on center studs
Recommended Mounting Hardware 5/16 x 2.5” Lag Bolts - three per side minimum 5/16 x 2.5” Lag Bolts - three per side minimum
System Enclosure Dimensions (H x W x D) Unit 31.3 x 17.25 x 12.9” (80 x 44 x 33 cm) 31.3 x 17.25 x 12.9” (80 x 44 x 33 cm)
Shipping 40.5 x 20.5 x 17.25” (103 x 52 x 44 cm) 40.5 x 20.5 x 17.25” (103 x 52 x 44 cm)
Battery Enclosure Dimensions (H x W x D) Unit 36.25 x 17.25 x 12.55” (92 x 44 x 32 cm) 36.25 x 17.25 x 12.55” (92 x 44 x 32 cm)
Shipping 43.25 x 20.25 x 16.75” (110 x 51 x 43 cm) 43.25 x 20.25 x 16.75” (110 x 51 x 43 cm)
System Weight Unit 107 lbs (49 kg) 107 lbs (49 kg)
Shipping 117 lbs (53 kg) 117 lbs (53 kg)
Battery Enclosure Weight (without batteries) Unit 29 lbs (13 kg) 29 lbs (13 kg)
Shipping 47 lbs (21 kg) 47 lbs (21 kg)
Certifications ETL certified to the UL1741 standard ETL certified to the UL1741 standard
Anti-Islanding Measures UL1741 compliant UL1741 compliant
Warranty 5 year limited repair warranty standard 5 year limited repair warranty standard
Field Installed Options MATE or MATE2 remote system display MATE or MATE2 remote system display
OBAC breakers for additional AC load circuits OBAC breakers for additional AC load circuits
OBPV breakers for PV array series string protection OBPV breakers for PV array series string protection