Panasonic UJ30 Work Light User Manual


 
Warning indications
47
Error codes
When an error occurs, the three-digit display will indicate the error code.
Display Error name Error description
E00 Interlock emergency stop
The interlock contact was opened during
irradiation.
CH1-4 E10 Connection error
The LED head was disconnected.
CH1-4 E20 LED break error
A circuit break was detected in the LED
head during irradiation.
CH1-4 E30 LED short-circuit error
A short-circuit of the LED head
was detected during irradiation.
CH1-4 E40 LED temperature error
The LED head temperature reached an
abnormal level.
CH1-4 E50 LED time error
The cumulative time of the LED has
reached the set replacement time.
CH1-4 E60 STEP1 calibration error
CH1-4 E61 STEP2 calibration error
CH1-4 E62 STEP3 calibration error
CH1-4 E63 STEP4 calibration error
CH1-4 E64 STEP5 calibration error
CH1-4 E65 STEP6 calibration error
CH1-4 E66 STEP7 calibration error
CH1-4 E67 STEP8 calibration error
CH1-4 E68 STEP9 calibration error
CH1-4 E69 STEP10 calibration error
The set UV intensity was not reached.