OEM Catalogue 2009/2010 3.109
HID Gear
D1
A2
B1
B2
A3
A1
C1
HID-DV
Type A1Nom A2Nom A3Nom B1Nom B2Nom C1Nom D1Nom
HID-DynaVision 1-10V SON/CDO 150.0 134.0 136.0 90.0 70.0 40.0 4.5
HID-DynaVision SON and CDO
Inrush current
Type Maximum
gear number
on MCB
(x)
Inrush
current
Peak
(A)
Inrush
current
Width
(ms)
HID-D 1-10V 100/150 SON/CDO 8 50 0.5
HID-D 1-10V 70 SON/CDO 12 35 0.5
Electrical data
Type Number
of
Lamps
(x)
Rated
Gear-
Lamp
Power
Line
Frequency
(Hz)
Line
Voltage
(V)
T-case
life
(ºC)
T-case
maximum
(ºC)
T-ambient Ignition
Voltage
(kV)
Cable-Cap
outputwires
mutual
(pF)
HID-D 1-10V 100 /S CDO 220-240V 1 100 50/60 220-240 90 100 50 4.00 200
HID-D 1-10V 100 /S SON 220-240V 1 100 50/60 220-240 90 100 50 4.00 1000
HID-D 1-10V 150 /S CDO 220-240V 1 150 50/60 220-240 90 100 45 4.00 200
HID-D 1-10V 150 /S SON 220-240V 1 150 50/60 220-240 90 100 45 4.00 1000
HID-D 1-10V 70 /S CDO 220-240V 1 70 50/60 220-240 90 100 50 2.50 200
HID-D 1-10V 70 /S SON 220-240V 1 70 50/60 220-240 90 100 50 2.50 1000
Ordering and packing data
Type Weight Qty bulk
packing
Dimensions bulk packing EAN code
bulk packing
EOC
8711500
HID-D 1-10V 100 /S CDO 220-240V 50/60Hz 0.725 kg 10 39.8 cm x 16 cm x 11.1 cm 8711500931337 931320 30
HID-D 1-10V 100 /S SON 220-240V 50/60Hz 0.725 kg 10 39.8 cm x 16 cm x 11.1 cm 8711500749062 749055 30
HID-D 1-10V 150 /S CDO 220-240V 50/60Hz 0.725 kg 10 39.8 cm x 16 cm x 11.1 cm 8711500538109 538093 30
HID-D 1-10V 150 /S SON 220-240V 50/60Hz 0.725 kg 10 39.8 cm x 16 cm x 11.1 cm 8711500538086 538079 30
HID-D 1-10V 70 /S CDO 220-240V 50/60Hz 0.725 kg 10 39.8 cm x 16 cm x 11.1 cm 8711500931351 931344 30
HID-D 1-10V 70 /S SON 220-240V 50/60Hz 0.725 kg 10 39.8 cm x 16 cm x 11.1 cm 8711500927330 927323 30
Electrical installation notes
Mains operation
Rated mains voltage 220 - 240 V
With tolerances for performance
+6%-8%
203 - 254 V
With tolerances for operation 180 - 264 V
Mains frequency 50/60 Hz
Power factor 100% power > 0.98
Power factor 35%, SON, 60%,
CDO, power
> 0.93
Earth leakage current < 0,5 mA per driver
Overvoltage protection 48 hrs at 325 Vac
2 hrs at 366 Vac
5 min. at 400 Vac
Lamp operation
Operation frequency (typical) 125 Hz
Ignition voltage 3 - 4 kV
Cable capacity
SON Max. 1 nF
CDO Max. 200 pF
Air and creepage distance from any
(metal) part that may become live,
to earthed environment (class I) or
test finger (class II)
> 4 mm