Porter-Cable 360 Sander User Manual


 
12
MAINTENANCE
KEEP TOOL CLEAN
Periodically blow out all air passages with dry compressed air. All plastic
parts should be cleaned with a soft damp cloth. NEVER use solvents to
clean plastic parts. They could possibly dissolve or otherwise damage the
material.
CAUTION: Wear safety glasses while using compressed air.
FAILURE TO START
Should your tool fail to start, check to make sure the prongs on the cord
plug are making good contact in the outlet. Also, check for blown fuses or
open circuit breakers in the line.
LUBRICATION
This tool has been lubricated with a sufficient amount of high grade lubricant
for the life of the unit under normal operating conditions. No further
lubrication is necessary.
FRAME PROTECTOR
The frame protector bar is made of hardened steel. It is located, to the left
and at the rear of the idler pulley and is fastened to the frame. This bar
protects the frame of the machine when tracking the abrasive belt. Always
adjust the belt so it moves evenly across (without rubbing) the protective
bar. When this bar becomes worn and uneven, replace it with a new one
(available from your Porter-Cable Service Center).
DRIVE PULLEY
The rubber-covered drive pulley at the rear of the machine is crowned or
tapered from the center to either side to make the abrasive belt run true and
in line with the idler pulley at the front of the machine. After considerable
use, the crown will wear away and the belt will begin to run off the side of
the pulley and cut into the guide block or frame. When the crown is worn to
this extent, have the drive pulley replaced by your Authorized Porter-Cable
Service Station. This action can be checked each time the abrasive belt is
replaced and tracked. After the belt is tracked to the front pulley, watch it for
a few seconds to see that it runs true and stays in place on the back pulley.
Avoid getting oil and grease on the rubber cover. It will cause it to fail.
BRUSH INSPECTION AND LUBRICATION
For your continued safety and electrical protection, brush inspection and
replacement on this tool should ONLY be performed by an AUTHORIZED
PORTER-CABLE SERVICE STATION or a PORTER-CABLE/DELTA
FACTORY SERVICE CENTER.
At approximately 100 hours of use, take or send your tool to your nearest
authorized Porter-Cable Service Station to be thoroughly cleaned and
inspected. Have worn parts replaced and lubricate with fresh lubricant. Have
new brushes installed, and test the tool for performance.
899713 - 04-12-02.qxd 9/23/02 1:50 PM Page 12