Porter-Cable C2025 Air Compressor User Manual


 
12 - ENGN000732
Air Compressor Pump (not shown): Compressesairintotheairtank.Working
air is not available until the compressor has raised the air tank pressure above that
required at the air outlet.
Drain Valve: The drain valve is located at the base of the
Drain
Valve
air tank and is used to drain condensation at the end of
each use.
Check Valve:Whentheaircompressorisoperating,the
check valve is "open", allowing compressed air to enter
theairtank.Whentheaircompressorreaches"cut
Check
Valve
out" pressure, the check valve "closes", allowing
air pressure to remain inside the air tank.
Motor Overload Protector (not shown): The
motor has an automatic reset thermal overload
protector. If the motor overheats for any reason,
the overload protector will shut off the motor.
The motor must be allowed to cool down before
restarting. The compressor will automatically
restart after the motor cools.
HOW TO USE YOUR UNIT
How to Stop
1. SettheOn/Offswitchto"Off".
Before Starting
Do not operate this unit until you read and understand this
instruction manual for safety, operation and maintenance instructions.
Break-in Procedure
Risk of Unsafe Operation. Serious damage may result if the
following break-in instructions are not closely followed.
This procedure is required before the air compressor is put into service and when
the check valve or a complete compressor pump has been replaced.
1. MakesuretheOn/Offswitchisinthe"Off"position.
2.
Plug the power cord into the correct branch circuit receptacle.
(RefertoVoltage
andCircuitProtectionparagraphintheInstallationsectionofthismanual.)
3. Openthedrainvalve(counterclockwise)fullytopermitairtoescapeandpre-
vent air pressure build up in the air tank during the break-in period.
4. MovetheOn/Offswitchto"On"position.Thecompressorwillstart.
5. Runthecompressorfor15minutes.Makesurethedrainvalveisopenand
there is minimal air pressure build-up in tank.
6. After15minutes,closethedrainvalvebyturningclockwise.Theairreceiver
will fill to "cut-out" pressure and the motor will stop.
The compressor is now ready for use.
Before Each Start-Up
1. SettheOn/Offswitchto"Off".
2. Turn the regulator knob counter-clockwise to set the outlet pressure to zero.
3. Attachhoseandaccessories.
Risk of unsafe operation. Firmly grasp air hose in hand when
installing or disconnecting to prevent hose whip.
Risk of unsafe operation. Do not use damaged or worn
accessories.