Porter-Cable CPLC7060V Air Compressor User Manual


 
11 - ENG D23269
OPERATION
Know Your Air Compressor
READ THIS OWNER’S MANUAL AND SAFETY RULES BEFORE OPERATING YOUR
UNIT. Compare the illustrations with your unit to familiarize yourself with the loca-
tion of various controls and adjustments. Save this manual for future reference.
Description of Operation
Become familiar with these controls before operating the unit.
On/Auto/Off Switch: Turn this switch ON to provide
automatic power to the pressure switch and OFF to
remove power at the end of each use.
Pressure Switch: The pressure switch automatically
starts the motor when the air tank pressure drops
below the factory set “cut-in” pressure. It stops the
motor when the air tank pressure reaches the facto-
ry set “cut-out” pressure.
Safety Valve: If the pressure switch does not shut
off the air compressor at its “cut-out” pressure set-
ting, the safety valve will protect against high pres-
sure by “popping out” at its factory set pressure
(slightly higher than the pressure switch “cut-out”
setting).
Tank Pressure Gauge: The tank pressure gauge
indicates the reserve air pressure in the tank.
Globe Valve (sold separately): Opens and closes air discharge valve. Turn knob
counter-clockwise to open and clockwise to close.
Drain Valve: The drain valve is located at the base of the
air tank and is used to drain condensation at the end of
each use.
Cooling System (not shown): This compressor contains
an advanced design cooling system. At the heart of this
cooling system is an engineered fan. It is perfectly normal
for this fan to blow air through the vent holes in large
amounts. You know that the cooling system is working when air is being expelled.
Air Compressor Pump (not shown): Compresses air into the air tank. Working air
is not available until the compressor has raised the air tank pressure above that
required at the air outlet.
Check Valve: When the air compressor is operating, the
check valve is “open”, allowing compressed air to enter the air
tank. When the air compressor reaches “cut-out” pressure,
the check valve “closes”, allowing air pressure to remain inside
the air tank.
Pressure Release Valve: The pressure release valve, located
on the side of the pressure switch, is designed to automatically
release compressed air from the compressor head and the
outlet tube when the air compressor reaches “cut-out” pres-
sure or is shut off. The pressure release valve allows the motor
to restart freely. When the motor stops running, air will be heard escaping from this
valve for a few seconds. No air should be heard leaking when the motor is running,
or continuous leaking after unit reaches “cut-out” pressure.
Pressure
Release
Valve
Check Valve
Pressure
Switch
On/Auto/Off
Switch
Safety
Valve
Tank
Pressure
Gauge
Globe Valve
Drain Valve