Porter-Cable CPLC7060V Air Compressor User Manual


 
3 - ENG D23269
RISK OF BURSTING
SA
VE THESE INSTRUCTIONS
IMPROPER OPERATION OR MAINTENANCE OF THIS PRODUCT COULD RESULT IN SERIOUS INJURY
AND PROPERTY DAMAGE. READ AND UNDERSTAND ALL WARNINGS AND OPERATING INSTRUC-
TIONS BEFORE USING THIS EQUIPMENT.
RISK OF EXPLOSION OR FIRE
AIR TANK: THE FOLLOWING CONDITIONS COULD LEAD TO A WEAKENING OF THE TANK, AND RESULT
IN A VIOLENT TANK EXPLOSION AND COULD CAUSE PROPERTY DAMAGE OR SERIOUS INJURY.
HAZARD
WHAT CAN HAPPEN
HOW TO PREVENT IT
IMPORTANT SAFETY INSTRUCTIONS (cont’d)
WHAT CAN HAPPEN
HOW TO PREVENT IT
IT IS NORMAL FOR ELECTRICAL CONTACTS
WITHIN THE MOTOR AND PRESSURE SWITCH TO
SPARK.
IF ELECTRICAL SPARKS FROM COMPRESSOR
COME INTO CONTACT WITH FLAMMABLE
VAPORS, THEY MAY IGNITE, CAUSING FIRE OR
EXPLOSION.
RESTRICTING ANY OF THE COMPRESSOR
VENTILATION OPENINGS WILL CAUSE SERIOUS
OVERHEATING AND COULD CAUSE FIRE.
UNATTENDED OPERATION OF THIS PRODUCT
COULD RESULT IN PERSONAL INJURY OR
PROPERTY DAMAGE. TO REDUCE THE RISK
OF FIRE, DO NOT ALLOW THE COMPRESSOR
TO OPERATE UNATTENDED.
ALWAYS OPERATE THE COMPRESSOR IN A
WELL VENTILATED AREA FREE OF COM-
BUSTIBLE MATERIALS, GASOLINE OR SOL-
VENT VAPORS.
IF SPRAYING FLAMMABLE MATERIALS, LOCATE
COMPRESSOR AT LEAST 20 FEET AWAY FROM
SPRAY AREA. AN ADDITIONAL LENGTH OF
HOSE MAY BE REQUIRED.
STORE FLAMMABLE MATERIALS IN A SECURE
LOCATION AWAY FROM COMPRESSOR.
NEVER PLACE OBJECTS AGAINST OR ON TOP
OF COMPRESSOR. OPERATE COMPRESSOR
IN AN OPEN AREA AT LEAST 12 INCHES AWAY
FROM ANY WALL OR OBSTRUCTION THAT
WOULD RESTRICT THE FLOW OF FRESH AIR TO
THE VENTILATION OPENINGS.
OPERATE COMPRESSOR IN A CLEAN, DRY, WELL
VENTILATED AREA. DO NOT OPERATE UNIT
INDOORS OR IN ANY CONFINED AREA.
ALWAYS REMAIN IN ATTENDANCE WITH THE
PRODUCT WHEN IT IS OPERATING.
ALWAYS DISCONNECT ELECTRICAL POWER
BY MOVING PRESSURE SWITCH LEVER TO
THE OFF POSITION AND DRAIN TANK DAILY
OR AFTER EACH USE.
1. FAILURE TO PROPERLY DRAIN CONDENSED
WATER FROM THE TANK, CAUSING RUST
AND THINNING OF THE STEEL TANK.
2. MODIFICATIONS OR ATTEMPTED REPAIRS
TO THE TANK.
3. UNAUTHORIZED MODIFICATIONS TO THE
UNLOADER VALVE, SAFETY VALVE, OR ANY
OTHER COMPONENTS WHICH CONTROL
TANK PRESSURE.
4. EXCESSIVE VIBRATION CAN WEAKEN THE
AIR TANK AND CAUSE RUPTURE OR
EXPLOSION.
A
TTACHMENTS & ACCESSORIES:
EXCEEDING THE PRESSURE RATING OF AIR
TOOLS, SPRAY GUNS, AIR OPERATED ACCESSO-
RIES, TIRES AND OTHER INFLATABLES CAN
CAUSE THEM TO EXPLODE OR FLY APART, AND
COULD RESULT IN SERIOUS INJURY.
DRAIN TANK DAILY OR AFTER EACH USE. IF
TANK DEVELOPS A LEAK, REPLACE IT IMMEDI-
ATELY WITH A NEW TANK OR REPLACE THE
ENTIRE COMPRESSOR.
NEVER DRILL INTO, WELD, OR MAKE ANY MOD-
IFICATIONS TO THE TANK OR ITS ATTACH-
MENTS.
THE TANK IS DESIGNED TO WITHSTAND SPECIF-
IC OPERATING PRESSURES. NEVER MAKE
ADJUSTMENTS OR PARTS SUBSTITUTIONS TO
ALTER THE FACTORY SET OPERATING PRES-
SURES.
FOR ESSENTIAL CONTROL OF AIR PRESSURE,
YOU MUST INSTALL A PRESSURE REGULATOR
AND PRESSURE GAUGE TO THE AIR OUTLET OF
YOUR COMPRESSOR. FOLLOW THE EQUIPMENT
MANUFACTURERS RECOMMENDATION AND NEV-
ER EXCEED THE MAXIMUM ALLOWABLE PRES-
SURE RATING OF ATTACHMENTS. NEVER USE
COMPRESSOR TO INFLATE SMALL LOW-PRES-
SURE OBJECTS SUCH AS CHILDREN’S TOYS,
FOOTBALLS, BASKETBALLS. ETC.