Trouble Probable Cause Remedy
Motor starter failure.
Examine motor starter for burned or
failed components. If damage is
found, replace motor starter. If motor
starter looks okay but is still suspect,
you have two options: have a
qualified electrician test the motor
starter for function, or purchase a new
starter and establish if that was the
problem on changeout.
If you have access to a voltmeter, you
can separate a starter failure from a
motor failure by first, verifying
incoming voltage at 220+/-20 and
second, checking the voltage
between starter and motor at 220+/-
20.
If incoming voltage is incorrect, you
have a power supply problem.
If voltage between starter and motor
is incorrect, you have a starter
problem.
If voltage between starter and motor
is correct, you have a motor problem.
Motor failure.
If electric motor is suspect, you have
two options: Have a qualified
electrician test the motor for function
or remove the motor and take it to a
quality electric motor repair shop and
have it tested.
Miswiring of the unit.
Check to confirm all electrical
connections are correct and properly
tight. Make any needed corrections.
Machine will not
start/restart or
repeatedly trips
circuit breaker or
blows fuses.
(cont.)
On/off switch failure.
If the on/off switch is suspect, you
have two options: Have a qualified
electrician test the switch for function,
or purchase a new on/off switch and
establish if that was the problem on
changeout.
Optional Accessories
2230002 Bed and Feed Roller Gauge
6292621 Knives, Single-Sided (set of 4) for model 209 only
1791212 Knife Inserts (set of 10) for model 209HH only
708520 DRO Scale Retrofit Kit
Replacement Parts
Replacement parts are listed on the following pages. To order parts or reach our service department, call
1-800-274-6848 between 7:30 a.m. and 6:00 p.m. (CST), Monday through Friday. Having the Model
Number and Serial Number of your machine available when you call will allow us to serve you quickly and
accurately.