11. Install the lower dust bag as follows:
Insert a retainer strap through the loops in the bag as
shown in Figure 13.
CAUTION: Retainer straps are rolled up
under tension. Hold strap with hand and
allow to unroll gradually.
Place the bag over the lip of the housing and secure
by fastening the retainer strap. Repeat for other lower
bag.
12. In the same fashion, install the upper bag with a
retainer strap over the top lip of the housing. (NOTE:
the upper bag has the Powermatic name on it). See
Figure 14. Place the top loop of the bag over the "hook"
on the hanger as shown. Repeat for other bag.
All bags should be securely fastened to the housings
with no air leaks.
13. Two adaptors are provided with the dust collec-
tor. Place one upon the inlet as shown in Figure 15. A
hole is provided on the inlet for a screw to secure a
hose or an adaptor to the machine.
ELECTRICAL CONNECTION
The dust collector is equipped with a 3 horsepower,
single phase, 230 volt, or three phase, 230/460 volt
motor. The unit is factory wired for 230 volts and
equipped with a 20 amp cord and plug set. The 230
volt plug requires a receptacle as illustrated in Figure
16.
The three phase motor may be reconnected for 460
volts by changing the connections as illustrated in the
diagram motor wiring box. The three phase power
cord is not equipped with a plug.
!